Abstract (English):
The paper presents generalized and updated results of modern researches dedicated to the use of the electron paramagnetic resonance dosimetry in forensic analysis of general and local radiation injuries. Promising areas are identified for further study of this issue.

Keywords:
electron paramagnetic resonance, electron paramagnetic resonance dosimetry, forensic analysis, general radiation injury, local radiation injury, ionizing radiation
Text
Text (PDF): Read Download
References

1. Swartz H.M., Flood A.B. EPR biodosimetry: challenges and opportunities // Radiat. Prot.Dosimetry. – 2023; 199(14):1441-1449. Doi:https://doi.org/10.1093/rpd/ncad009

2. Trompier F., Queinnec F., Bey E. et al. EPR retrospective dosimetry with fingernails: report on first application cases // Health Phys. – 2014; 106(6):798-805. Doi:https://doi.org/10.1097/HP.0000000000000110

3. Romanyukha A., Trompier F., Reyes R.A. Q-band electron paramagnetic resonance dosimetry in tooth enamel: biopsy procedure and determination of dose detection limit // Radiat. Environ. Biophys. – 2014; 53(2):305-10. Doi:https://doi.org/10.1007/s00411-013-0511-8

4. Kvacheva Yu.E., Glazunov A.G. Osobennosti organizacii i proizvodstva sudebno-medicinskoy ekspertizy trupov lic, pogibshih ot ostroy luchevoy bolezni // Sudebno-medicinskaya ekspertiza. – 2012. – T. 55, № 2. – S. 43–45.

5. Williams B.B., Dong R., Kmiec M. et al. Development of in vivo tooth EPR for individual radiation dose estimation and screening // Health Phys. – 2010; 98(2):327-38. Doi: 10.1097/ HP.0b013e3181a6de5d

6. Swartz H.M. Using stable free radicals to obtain unique and clinically useful data in vivo in human subjects // Radiat. Prot. Dosimetry. – 2016; 172(1-3):3-15. Doi:https://doi.org/10.1093/rpd/ncw323

7. Flood A.B., Williams B.B., Schreiber W. et al. Advances in in vivo EPR Tooth biodosimetry: meeting the targets for initial triage following a large-scale radiation event // Radiat. Prot. Dosimetry. – 2016; 172(1-3):72-80. Doi:https://doi.org/10.1093/rpd/ncw165

8. Swarts S.G., Sidabras J.W., Grinberg O. et al. Developments in biodosimetry methods for triage with a focus on X-band electron paramagnetic resonance in vivo fingernail dosimetry // Health Phys. – 2018; 115(1):140-150. Doi:https://doi.org/10.1097/HP.0000000000000874

9. IAEA. Incident and Trafficking Database (ITDB). https://www.iaea.org/resources/ databases/itdb

10. Zdravkova M., Crokart N., Trompier F. et al. Non-invasive determination of the irradiation dose in fingers using low-frequency EPR // Phys. Med. Biol. – 2004; 49(13):2891-8. Doi:https://doi.org/10.1088/0031- 9155/49/13/009

11. Kvacheva Yu.E., Kovalev A.V., Gribunov Yu.P., Shestakova I.N. Smertel'naya radiacionnaya travma vsledstvie umyshlennogo primeneniya istochnika ioniziruyuschego izlucheniya v protivopravnyh celyah // Sudebno-medicinskaya ekspertiza. – 2024. – № 2. – S. 39–42. Doi:https://doi.org/10.17116/sudmed20246702139

12. Marciniak A., Ciesielski B., Juniewicz M. EPR dosimetry in glass: a review // Radiat. Environ. Biophys. – 2022; 61(2):179-203. Doi:https://doi.org/10.1007/s00411-022-00970-w